FK-CT20 Scientific soil nutrient detector

Short Description:

Measurement items

Soil: ammonium nitrogen, available phosphorus, available potassium, organic matter, alkali hydrolyzable nitrogen, nitrate nitrogen, total nitrogen, total phosphorus, total potassium, available calcium, available magnesium, available sulfur, available iron, available manganese, available boron, available zinc, available copper, available chlorine, available silicon, pH, salt content and water content;

Fertilizer: nitrogen, phosphorus and potassium in simple fertilizer and compound fertilizer. Nitrogen, phosphorus, potassium, humic acid, pH value, organic matter, calcium, magnesium, sulfur, silicon, iron, manganese, boron, zinc, copper and chlorine in organic fertilizer and foliar fertilizer (spraying fertilizer).

Plant: N, P, K, CA, Mg, S, Si, Fe, Mn, B


Product Detail

Product Tags

Function introduction

1. Operating system: Android operating system, the main control must use multi-core processor, CPU frequency ≥ 1.8GHz, large capacity memory, fast operation speed, strong stability, no stuck phenomenon. With USB dual interface, the upload data can be exported quickly.

2. The instrument adopts 7.0-inch large screen Chinese character backlight display, can store and print test results, and has the function of historical data query and printing.

3. There is no need to make blank and standard samples for testing. Compared with other instruments, the operation steps, operation time and reagent consumption are reduced by half. The samples are read directly to eliminate the errors caused by traditional blank standard samples and ensure the accuracy of test results.

4. 12 channel rotary colorimetric cell (non solid module), which can detect 12 samples at the same time. Each sample can select different detection items, and rotate automatically. It has the function of reminding each channel to complete the detection.

5. The instrument has its own protection function, which can set user name and password; Equipped with fingerprint lock for fingerprint login, prevent non staff operation to view the experimental data.

6. Built in crop Atlas: according to the pictures of nutrient deficiency of each crop, compare the leaf surface, and diagnose the abundance and deficiency.

7. Data printing: the built-in thermal printer can print out the detection items, detection units, detection personnel, detection time, channel number, absorbance, content (mg / kg), two-dimensional code and other information.

8. Built in advanced locator to achieve accurate positioning of each channel;;

9. The instrument is equipped with four kinds of wavelength light sources (red, blue, green and orange). The wavelength of the light source is stable, the service life is up to 100000 hours, the reproducibility is good, and the accuracy is high.

10. the instrument is equipped with voltage display lamp, which displays the current voltage value in real time to ensure the stable voltage state of the operation process, and has the function of power off protection. In case of sudden power failure, the data can be stored automatically to prevent data loss

11. Simultaneous extraction and determination of fast available N, P, K and other nutrients in soil.

12. Detection speed: under normal proficiency level, it takes about 20 minutes to detect soil ammonium nitrogen, phosphorus and potassium (including soil sample pretreatment and chemical preparation), about 50 minutes to detect fertilizer nitrogen, phosphorus and potassium, and about 20 minutes to detect single trace element.

Technical index

1. Power supply: AC 220 ± 22V DC 12V + 5V (large capacity lithium battery inside the instrument)

2. Power: ≤ 5W

3. Range and resolution: 0.001-9999

4. Repeatability error: ≤ 0.04% (0.0004, potassium dichromate solution)

5. Instrument stability: drift less than 0.3% (0.003, transmittance measurement) in one hour. After the instrument is started and preheated for 5 minutes, the display number will not drift within 30 minutes (light transmittance measurement); Within one hour, the digital drift shall not exceed 0.3% (transmittance measurement) and 0.001 (absorbance measurement); 5% (0. 005, transmittance measurement) within two hours.

6. Linear error: ≤ 0.2% (0.002, copper sulfate detection)


  • Previous:
  • Next:

  • Write your message here and send it to us

    Related products

    • Portable ATP fluorescence detector FK-ATP

      Portable ATP fluorescence detector FK-ATP

      Instrument characteristics High sensitivity - 10-15-10-18 mol / L High speed - the conventional culture method is more than 18-24 hours, while ATP only takes more than ten seconds Feasibility - there is a clear correlation between the number of microorganisms and the ATP content in microorganisms. By detecting ATP content, the number of microorganisms in the reaction can be obtained indirectly Operability - the tr...

    • Soil four parameter detector

      Soil four parameter detector

      Technical Parameters Volumetric water content of soil: Unit: % (m3/m3); Test sensitivity: ± 0.01% (m3/m3); measuring range: 0-100% (m3/m3). Measurement precision: within the range of 0-50% (m3/m3) ± 2% (m3/m3); 50-100% (m3/m3) ± 3% (m3/m3); resolution: 0.1% Soil temperature range: -40-120 ℃. Measurement precision: ± 0.2 ℃. Resolution: ± 0.1 ℃ Soil salinity range: 0-20ms. Measurement precision: ± 1%. Resolution: ±...

    • High precision plant respiration meter FK-GH10

      High precision plant respiration meter FK-GH10

      Technical index Carbon dioxide detection Detection principle: Infrared Minimum measurement range: 0-2000ppm Linearity: ≤± 1% F.S Repeatability: ≤± 1% Response time: ≤ 15s Zero drift: ≤± 2% f.s/24h End point drift: ≤± 2% f.s/24h Oxygen detection Detection principle: electrochemical Measurement range: 0-30% Linearity: ≤± 2% F.S Repeatability: ≤± 1% Response time: 30s Zero drift: ≤± 2% f.s/24h End point drift: ≤± 2% ...

    • FK-HT300 High precision soil fertilizer nutrient detector for scientific research

      FK-HT300 High precision soil fertilizer nutrien...

      Detection Speed Simultaneous extraction and determination of fast available N, P, K and other nutrients in soil at one time. Detection speed: at the normal proficiency level, it takes about 20 minutes to detect soil ammonium nitrogen, phosphorus and potassium (including soil sample pretreatment and chemical preparation), about 50 minutes to detect fertilizer nitrogen, phosphorus and potassium, and about 20 minutes...

    • Energy dispersive X-ray fluorescence spectrometer

      Energy dispersive X-ray fluorescence spectrometer

      Product name and model index introduction Product name and model: Energy dispersive X-ray fluorescence spectrometer ------ R-350 Working conditions ● operating temperature: 15-30 ℃ ● relative humidity: 40% ~ 50% ● power supply: AC: 220V ± 5V Technical performance and index 1. Elemental analysis ranges f...

    • Portable plant canopy analyzer FK-G10

      Portable plant canopy analyzer FK-G10

      Functional features The plant canopy measuring instrument is an integrated design, including LCD, operation key, storage SD card and measuring probe, which is suitable for field data acquisition. The instrument has the advantages of simple operation, small volume and convenient carrying. The storage medium used in the instrument is SD card which is widely used in the market. It has large storage capacity and conve...